| Parameter | Value |
|---|---|
| Model | G12-400 |
| Supported Takeoff Weight | 1~2kg, suggested values, data for reference only |
| Flight Altitude / Cable Length | 30m or 50m, with 33m or 55m Standard configuration optional cable |
| Endurance | >24h, continuous power supply from the ground unit |
| Input Voltage (Ground Module) | 190~240VAC, Single-phase 220VAC@50/60Hz |
| Tether Output Voltage | 600~850VDC, Factory default 850VDC |
| Ground Module Output Power | 1200W (rated long-time output), 1500W (peak) |
| Air Module Input / Output Voltage | 600~850VDC / 16.5VDC or 25VDC |
| Air Module Output Power | 400W (rated long-time output), 500W (peak) |
| Cable Reel Speed / Pulling Force | 0~3m/s · 0~10N, intelligent continuous adjustment |
| Control Modes / Data Monitoring | Button · Voltage, current, temperature, power consumption, outlet length, operating tim |
| Protection & Warning | overvoltage · Fault content displayed on screen |
| Cable Material / Interfaces | Silver-plated copper+Teflon insulation+Sheath film+Kevlar weaving · LP12, LP12, Switch, Bluetooth antenna, Type-C |
| Environment / Protection Class | -20~45℃ working · storage -40~65℃C · air module IP54, ground module IPx4 |
| Packing Case (Size / Weight) | Trolley case, D495×W410×H220mm · 3kg |
Values verified against the official CEEIC G12-400 product page.




| Code Segment | Meaning |
|---|---|
| G | Series prefix — tethered power system (ground module + air module) |
| 12 | Cable class up to 55m (G12 = 55m · G35 = 110m · G70 = 220m · G300 = 330m) |
| 400 | Rated air-module output power 400W (400 = 400W · 1 = 1kW · 9 = 9kW) |
Available models in this range: G12-400 · G12-1 · G35-2 · G35-3 · G70-3 · G70-6 · G300-9 · G300-12