| Parameter | Value |
|---|
| Model | CAB 500-C Series — SP1 / SP2 / SP5 / SP5-001 / SP5-002 / SP5-012 / SP7 / SP10 / SP77 |
| Sensor Technology | Open loop fluxgate, ISO 26262 ASIL-capable design |
| Nominal Current / Measuring Range | 500 A · ±500 A (DC), clamping ±530 A |
| Output Signal | High-speed CAN 2.0B, 500 kbps, configurable CAN ID / baudrate / frame period, 10 ms cyclic |
| Supply Voltage | 8–16 V DC, unipolar +12 V battery supply |
| Current Consumption | 40 mA typ. @ IP = 0 A · 140 mA typ. @ IP = 500 A (UC = 13.5 V) |
| Accuracy | ±1.5 A (±0.3 %) at 25 °C · ±2.5 A (±0.5 %) over −40 °C … +85 °C |
| Linearity | ±0.1 % at room temperature |
| Response Time | 150 ms start-up · 100 Hz CAN output rate (10 ms frame) |
| Operating Temperature | −40 °C … +85 °C |
| Isolation / Creepage | 2.5 kV AC (50 Hz, 1 min) · creepage 7.2 mm · clearance 6.95 mm |
| Mounting / Housing | Panel or busbar mounting, metal insert ears or plastic rivet (max 70 N) · PBT-GF30, IP42 |
| Dimensions / Weight | 67–70 g depending on variant (see outline drawing for dimensions) |
| Application | HEV / EV battery pack, lead-acid battery monitoring, BMS SOC / SOH / SOF |