| Parameter | Value |
|---|
| Model | CAB 1500-000 / 001 / 005 |
| Sensor Technology | Open loop fluxgate, ISO 26262 compliant design |
| Nominal Current / Measuring Range | 1500 A · ±1500 A (DC) · withstand peak 1700 A |
| Output Signal | High-speed CAN 2.0B, 500 kbps, configurable CAN ID / speed, 10 ms cyclic |
| Supply Voltage | 9–16 V DC @ ±1500 A · 8–16 V DC @ ±1000 A, unipolar +12 V battery |
| Current Consumption | 50 mA typ. @ IP = 0 A · 430 mA typ. @ IP = ±1500 A |
| Accuracy | ±0.5 % over −40 °C … +85 °C (average over 20 CAN frames / 200 ms) |
| Linearity | ±0.1 % at room temperature |
| Response Time | 150 ms start-up · 10 ms overload recovery |
| Bandwidth | DC … 20 Hz (10 ms CAN frame period) |
| Operating Temperature | −40 °C … +85 °C |
| Isolation / Creepage | 3.5 kV AC (50 Hz, 1 min) · creepage / clearance 12.5 mm |
| Mounting / Housing | Busbar (000 / 005) or panel (001) mounting, M6 · IP41 |
| Dimensions / Weight | 94 g ±5 % (busbar) · 91 g ±5 % (panel) |
| Application | EV / HEV battery pack and BDU current monitoring, 800 V systems (IEC 60664-1) |